Description
Fire rated calcium silicate board is used on duct enclosures, wall lining, ceiling fire layers, and equipment protection covers when the site needs heat, fire, sound, or condensation control in a controlled layer. The product has to follow real edges and support points, so non-combustible board layer is checked before packing. The final supply is based on board thickness, density, and fire report by system, the required surface, and the method used to close seams.

Product Parameters
|
Parameter |
Specification |
|
Product Structure |
Calcium silicate fire board + rock wool core composite board |
|
Core Density |
Calcium silicate board 170 kg/m³; rock wool 55-180 kg/m³ |
|
Core Thickness |
Calcium silicate board 6mm-20mm; rock wool 30-200mm |
|
Thermal Conductivity |
Calcium silicate board ≤0.055 or ≤0.078 W/(m·K); rock wool ≤0.043 W/(m·K) |
|
Combustion Grade |
Class A non-combustible |
|
Fire Resistance |
1 h or 2 h by tested composite board system |
|
Use Match |
Smoke exhaust duct and fire-rated enclosure system |
|
size |
2440mm x 1220mmx6mm-20mm Customization supported |
Product Advantages
The main benefit of fire rated calcium silicate board is that size, grade, and outer surface can be discussed before production instead of changed after arrival.
When the correct fixing method is chosen, the material can reduce loose joints around corners and hanger points.
Surface checking before packing helps find crushed edges, broken facing, or wrong roll marks early.

Certifications & Qualifications

For fire rated calcium silicate board, do not use the Rock Wool Board certificate as the calcium silicate certificate. The document set should follow the calcium silicate board and tested fire system.
Company system qualifications available in the company document set: Quality Management System Certificate (Certificate No. FAP25259601QRO, GB/T 19001-2016 / ISO 9001:2015), Environment Management System Certificate (Certificate No. FAP25259601ERO, GB/T 24001-2016 / ISO 14001:2015), and Occupation Health And Safety Management System Certificate (Certificate No. FAP25259601SRO, GB/T45001-2020 / ISO 45001:2018).
Relevant reference documents in the product manual include fire-rated duct system information, GB/T17428 ventilation duct fire test method, JC/T564.1-2018 for asbestos-free calcium silicate board, and 20K607 duct fire-protection design details.
If the board is used together with rock wool in a composite system, the Rock Wool Board UDEM certificate No. M.2025.206.C125155 can only support the rock wool layer, not the calcium silicate board name.
Before shipment, attach the matching test report, TDS, packing list, label photos, and customs documents according to the final board system.
FAQ
Hot Tags: fire rated calcium silicate board, China fire rated calcium silicate board manufacturers, suppliers, factory