Description
Reinforced Duct Fire Protection Wrap is intended for routes that need both insulation and a more durable external layer. The reinforced facing helps protect the surface while pieces are fitted around duct corners, pipe sections, and maintenance openings. Supply dimensions, core density, seam closure, and edge treatment are set from the approved system so the wrap can be installed without altering the main route.

Product Parameters
|
Parameter |
Specification |
|
Material / Core |
Aluminum silicate needled blanket with foil or reinforced facing; silicate or calcium silicate fire layer by system |
|
Size |
7200 x 610 mm x20mm/30mm |
|
Thickness |
20 mm-60 mm,80 mm |
|
Density |
96 kg/m³ for aluminum silicate blanket; 120±10 kg/m³ rock wool core where composite board is used |
|
Fire Resistance |
0.5 h,- 3h by tested duct wrap system |
|
Thermal Conductivity |
Rock wool core ≤0.043 W/(m·K); calcium silicate board ≤0.055 or ≤0.078 W/(m·K) by report |
|
Packing |
Roll or carton; packing mark follows size, thickness, and fire-resistance level |
Quality Check
For each Reinforced Duct Fire Protection Wrap
order, we verify the marked thickness, cut size, facing condition, and package label before loading.
Corners are checked for crushing, surfaces for looseness, and accessory quantities for shortages. Tape, fixings, or fittings are counted separately when they form part of the material schedule.

Certifications & Qualifications

The document pack is divided into three parts: company management certificates, the fire-test evidence for the complete build-up, and any conformity document that applies to an individual layer.
The company holds Quality Management System certificate FAP25259601QRO (GB/T 19001-2016 / ISO 9001:2015), Environment Management System certificate FAP25259601ERO (GB/T 24001-2016 / ISO 14001:2015), and Occupational Health and Safety Management System certificate FAP25259601SRO (GB/T 45001-2020 / ISO 45001:2018).
One related material file is the UDEM Technical Inspection Attestation of Conformity for Aluminum Silicate Needled Blanket under EN 13162:2012+A1:2015, certificate M.2025.206.C125156.
That document supports only the aluminum silicate blanket layer. A calcium silicate board or composite duct-wrap structure must be tied to the correct test report and project material list.
Before shipment, the certificate image, system report, packing list, and customs records can be checked against the final Reinforced Duct Fire Protection Wrap construction.